Flare Knock Out Tanks
Double Wall Flare Knock Out
AGI can design and build a Double Wall Heated Flare Knock Out Tank to meet your needs. AGI’s design allows you to have pressure up to 14.9 psi. No dike is required because of the 110% containment. At AGI we have our own in house tank lining and insulating facility. Our quality is very high and documented. | |
Standard FeaturesGuidelines of the Pressure Vessel Handbook, 8th EditionContainment Design: Guidelines of ULC-S653-94Meets ERCB D551/4″ steel tank shell3/8″ steel tank dished heads10 gauge steel containment shell & headsDesign Pressure: 50 PSI – MAWP: 14.9 PSI (nonregistered)24″ bolted tank manway8″ Inlet and outlet RFWN flange c/w internal steel deflector4″ gauge RFWN flange c/w slotted stinger for level gauge3″ drain RFWN flange c/w piping through cabinet1″ containment test 3000 lbs cplg c/w ball valveInsulated steel supports/ cabinet c/w lockable doorPropane / Natural Gas Cata-dyne heaterSandblasted to SSPC-SP6 (brush blast)Urethane insulation with black elastomeric seal |
Click here for more details on Flare Knock Out Tanks
Optional FeaturesLadder or Access StairsTank lining Devoe, Enviroline Philips etc..Heavy duty I- beam skidsCustom colorsLevel GaugeAluminum clad insulationGlycol coil heatCustom sizes and capacitiesSide manways |
Capacity | Length | Diameter | Weight | |||
25 bbl | 120″ | 3048 mm | 48″ | 1219 mm | 5,500 lbs | 2495 kg |
60 bbl | 120″ | 3048 mm | 72″ | 1829 mm | 9,200 lbs | 4173 kg |
110 bbl | 240″ | 6096 mm | 72″ | 1829 mm | 15,000 lbs | 6804 kg |